The energy farmers need, and what would carry it
Every registered farmer counted on the platform cost model · planning estimate, measure before sizing
Farmers counted
20
Electricity demanded
4.87 GWh/yr
Diesel & fuel demanded
222.9k L/yr
Energy cost today
R19.6m/yr
Solar PV to carry it
3,339 kWp
Battery storage
5,744 kWh
Supply capex
R93.5m
Net saving
R9.3m/yr
Energy demanded
What all 20 farmers need
- Farmers counted
- 20
- 14 from records · 6 on farm profiles
- Electricity demanded
- 4.87 GWh/yr
- R14.6m/yr at R3.00/kWh
- Diesel & fuel demanded
- 222.9k L/yr
- R5.0m/yr net of the SARS refund
- Peak load
- 2,226 kW
- sum of farm peaks · 0 farms off grid today
- Heat & brooding
- —
- no poultry or dairy heat load recorded
- Biogas from herds
- —
- no dairy or beef herd counted
Platform cost model per farm; farms without production detail counted on the documented farm profiles.
Holistic supply to carry it
What We Earth would supply, priced
- Solar PV
- 3,339 kWp
- R46.7m at R14,000/kWp · 19 farms with a load
- Battery storage
- 5,744 kWh
- R46.0m at R8,000/kWh · 40% critical × 4 h
- Farm digesters
- —
- no herd large enough for a farm digester
- Solar pumping
- 10 packages
- R800k at R80,000 per 20 ha
- Supply capex
- R93.5m
- PV + batteries + digesters + solar pumps, planning estimate
- Net saving
- R9.3m/yr
- 10 yr payback on PV + batteries
From our price list: ≈ R93.5m once-off for the advised systems · 6 items still to be quoted
Sum of every farm record's advised system at the documented rates (Solar Guide R14,000/kWp and R8,000/kWh; platform digester and pump packages). Measure before sizing.
Energy systems & facilities
What We Earth can build for a farm, a cluster or a district
Reference sites
Concept designs from the proposals — evidence, not offers
Scroll for more →
District intelligence · funding pipeline · impact
The energy need of this clientele, counted
- Electricity need
- 4.87 GWh/yr
- R14.6m/yr at R3.00/kWh
- Diesel & fuel need
- 222.9k L/yr
- R5.0m/yr net of the SARS refund
- Farmers in the pipeline
- 20
- 14 from records · 6 on farm profiles
- Indicative PV to carry it
- 3,339 kWp
- ≈ R46.7m at R14,000/kWp · Documented benchmark
- Biogas from recorded herds
- —
- 0 farms with heat or brooding loads
- Off grid today
- 0
- 0 no electricity · 0 on generators
| District | Farmers | Electricity | Diesel | Biogas | Energy cost / yr |
|---|---|---|---|---|---|
| City of TshwaneGauteng | 2 | 2.66 GWh/yr | 127.7k L/yr | — | R10.8m |
| OR TamboEastern Cape | 7 | 1.20 GWh/yr | 54.4k L/yr | — | R4.8m |
| Tshwane MetroGauteng | 1 | 397.8 MWh/yr | 11.9k L/yr | — | R1.5m |
| iLembeKwaZulu-Natal | 1 | 272.6 MWh/yr | 9.5k L/yr | — | R1.0m |
| WaterbergLimpopo | 2 | 253.3 MWh/yr | 10.4k L/yr | — | R993k |
| City of JohannesburgGauteng | 1 | 36.5 MWh/yr | 0 L/yr | — | R110k |
+4 more districts in the pipeline.
Energy needs by place — target the market, click a district, get the siting advice. All sections count the 20 farms in view.
Energy needs by place
Pick who the programme targets, then click a district
The wash is where that kind of energy need is concentrated on the live register — cream is a light holding, teal a middle holding, navy the heaviest mass in view. Click a district for where to build, how big, what it costs and what it earns.
Districts in view
Select a district on the map or in the list. The plan, costing and facility advice appear for that district only.
How the numbers are made
One calculation chain, one cost ladder, no invented norms
- 1
Farm loads
kW × hours → kWh/day
- 2
Water & pumps
0.002725 × V × H ÷ η
- 3
PV
kWp = kWh/day ÷ (5.0 PSH × 0.80 PR)
- 4
BESS
critical kW × 4 h ÷ 0.62
- 5
Cluster
0.65 × Σ peaks · 3I²R feeder check
- 6
Economics
capex ÷ grid cost avoided
Planning cost ladder (R/kWh)
- Solar PV · lowest routine energy — maximise daytime self-consumptionR1.10
- Grid off-peak · flexible pumping and schedulable loadsR1.65
- Grid blended · reference operating cost for savings and paybackR3.00
- Diesel genset · backup and emergency onlyR6.60
Both technical proposals, p4. Grid and diesel refresh from the LiveIndicators feed when the app has one. PV capex R14,000/kWp (PV-only, "not an EPC quotation"); BESS R8,000/kWh (Solar Guide benchmark); yield 1,650 kWh/kWp/yr.
Worked example — WeEarth Farm Energy Formula Summary
A dairy with a 100 kW cooling system running 10 hours and a 50 kW milking system running 4 hours:
(100 × 10) + (50 × 4) = 1,200 kWh/day = 1.2 MWh/day
Pumping: a farm moving 100 m³ through 50 m of head at 70% efficiency needs 0.002725 × 100 × 50 ÷ 0.70 = 19.46 kWh.
E_day = Σ(P × h × n × LF) · E_week = P × h × d · E_month = E_day × D · E_year = Σ(P × h × d).